How do you wake up a Battleborn battery?
To wake up a Battle Born lithium battery, first ensure it hasn’t entered a deep discharge protection mode. Use a compatible LiFePO4 charger set to 14.4–14.6V (for 12V systems) to initiate a slow charge for 1–2 hours. If unresponsive, temporarily parallel-connect a healthy battery to bypass the BMS low-voltage cutoff. Pro Tip: Never use lead-acid chargers—their equalization modes can damage lithium cells.
How Long Can You Expect Your Battle Born Battery to Last?
What triggers sleep mode in Battle Born batteries?
Sleep mode activates when voltage drops below 10V (12V models) to prevent cell damage. This occurs during prolonged storage or parasitic loads. BMS protection disconnects output until voltage recovers via charging.
Battle Born’s battery management system (BMS) initiates sleep mode at critically low voltages—typically 9.5–10V for 12V models. This safeguards against irreversible lithium plating. For example, a battery drained by a forgotten RV light might require wake-up charging. Pro Tip: Regularly monitor voltage with a Bluetooth-enabled shunt to avoid unexpected shutdowns. Transitionally, while lead-acid batteries tolerate deeper discharges, lithium chemistries demand stricter voltage floors. But what if the BMS remains locked? A controlled jump-start from another lithium battery often resets it without tripping protection protocols.
How to safely bypass BMS protection?
Temporarily connect a charged donor battery in parallel for 15–30 minutes. This raises system voltage above 12V, letting the BMS resume normal operation.
Use 10AWG cables to link the Battle Born’s terminals to a healthy 12V lithium or AGM battery. The donor’s higher voltage (13.2V+) tricks the BMS into re-enabling output. For instance, marine users often employ trolling motor batteries as temporary voltage sources. Transitionally, this method works because the BMS prioritizes system voltage over individual cell states initially. Why not use a power supply? Most lack the current stability needed for safe BMS handshaking. After revival, immediately charge normally to 14.6V for cell balancing.
Method | Success Rate | Risk Level |
---|---|---|
Parallel Battery | 85% | Low |
Power Supply | 40% | Moderate |
Battery Expert Insight
FAQs
Only if the charge controller delivers ≥13V continuously for 10+ minutes—most PWM controllers lack this capability. MPPT controllers with lithium profiles work best.
How long does wake-up charging take?
Typically 30–90 minutes before the BMS re-engages. Full recovery requires 4–6 hours to reach 100% state of charge.